2,664 research outputs found

    Suppression of long-wavelength CMB spectrum from the no-boundary initial condition

    Full text link
    The lack of correlations at the long-wavelength scales of the cosmic microwave background spectrum is a long-standing puzzle and it persists in the latest Planck data. By considering the Hartle-Hawking no-boundary wave function as the initial condition of the inflationary universe, we propose that the power suppression can be the consequence of a massive inflaton, whose initial vacuum is the Euclidean instanton in a compact manifold. We calculate the primordial power spectrum of the perturbations, and find that as long as the scalar field is moderately massive, the power spectrum is suppressed at the long-wavelength scales.Comment: 9 pages, 7 figures; journal versio

    Improving Axial Resolution of Optical Resolution Photoacoustic Microscopy with Advanced Frequency Domain Eigenspace Based Minimum Variance Beamforming Method

    Full text link
    Optical resolution photoacoustic microscopy (OR-PAM) leverages optical focusing and acoustic detection for microscopic optical absorption imaging. Intrinsically it owns high optical lateral resolution and poor acoustic axial resolution. Such anisometric resolution hinders good 3-D visualization; thus 2-D maximum amplitude projection images are commonly presented in the literature. Since its axial resolution is limited by the bandwidth of acoustic detectors, ultrahigh frequency, and wideband detectors with Wiener deconvolution have been proposed to address this issue. Nonetheless, they also introduce other issues such as severe high-frequency attenuation and limited imaging depth. In this work, we view axial resolution improvement as an axial signal reconstruction problem, and the axial resolution degradation is caused by axial sidelobe interference. We propose an advanced frequency-domain eigenspace-based minimum variance (F-EIBMV) beamforming technique to suppress axial sidelobe interference and noises. This method can simultaneously enhance the axial resolution and contrast of OR-PAM. For a 25-MHz OR-PAM system, the full-width at half-maximum of an axial point spread function decreased significantly from 69.3 μ\mum to 16.89 μ\mum, indicating a significant improvement in axial resolution

    Synthesis and crystal structure of the first 6a-thiathiophthen metal complex [Mo(CO)_5PPh_(2]2)(µ-C_5H_2S_3)

    Get PDF
    The first 6a-thiathiophthen metal complex was prepared by treating M(CO_)5[PPh_2CS_2CH_2C≡CH] with a catalytic amount of secondary amine or tertiary amine; the structure of the 6a-thiathiophthen molybdenum complex is confirmed by an X-ray diffraction analysis
    • …
    corecore